Scientific... Medical... Industrial... Clinical...
Home
About Us
Product Divisions
Medical Engineering
Infection Control
Press Releases
Technical Services
Company Newsletter
Recruit
Contact Us
        
Scientific Product Range
      
Dissolution Software
Dani Instrument Solutions
Gel Doc Systems
HPLC
Mass Spectrometry
Tablet Dissolution Systems
PSS - Polymer Standards Service
Fibreoptic Dissolution
FTIR / NIR
Spectrophotometry
Microplate Readers
      
Atomic Absorption Spectrometer
      
      
contrAA®300 – The High-Resolution Continuum Source Atomic Absorption Spectrometer for Flame and Hydride Technique
      
High-Resolution Continuum Source AAS (HR-CS AAS) covers the complete spectral range from the near vacuum-UV to the near infrared with a single continuum source, providing innovative capabilities. For the first time, genuine sequential multi-element analysis is implemented in AAS without the need for a multitude of different light sources. contrAA® is closing the gap between ICP and AAS!

Unique Flexibility

The xenon short-arc lamp as a continuum source is ideal for any element to be analyzed. No matter how frequently or seldom you have to determine an element, the HR-CS AAS instrument is immediately ready for measurement. You have every freedom for line selection, as the source covers the entire continuous wavelength range. All absorbing atom lines are immediately available, irrespective of the emission properties of the HCL (such as windows transmissive to UV or visible radiation). In addition, several new types of lines can be used for analysis.

Immediate Readiness for Measurement

The immediate readiness for measurement provided by HR-CS AAS is due to the fact that the lamp needs no fixed warm-up time to avoid output drift. Innovative correction algorithms continuously compensate any drift or fluctuation of the spectrometer including the source.

Improved Performance

HR-CS AAS features an improved signal-to-noise ratio and markedly better detection limits. This is due to the higher radiation density of the Xe continuum source compared to HCLs, and the enormously increased quantum efficiency of a CCD semiconductor detector compared to the photomultiplier tube commonly used in line-source AAS (LS AAS). HR-CS AAS is the first technique that c an efficiently correct spectral interferences in flame AAS by structured flames or molecule structures. This provides improved simultaneous background correction, and capabilities to correct spectral interferences to increase the accuracy of analytical results.

      
If you would like further information on this product, please click here
      
        
        
        
        
Brennan & Company - 61 Birch Avenue, Stillorgan Industrial Park, Stillorgan, Co. Dublin, Ireland
        
Phone: +353-1-295 2501        Fax: +353-1-295 2333        Email: enquiries@brennanco.ie